Make Rebar length independent of plan units

I would like to request that you make an option available to make the units for the bar presentation different from the units that I work with in plan. I tend to work with inches when I am adjusting the geometries of slabs and bars because working...
Guest 7 months ago in  0 Future consideration

Check the number of stirrup legs required for beams per ACI 318-19 9.7.6.2.2

In ACI 318-19, they added a maximum spacing between stirrup legs in beams. I think the program bars generated in RAM concept should increase the number of legs to meet this criteria.
Guest about 2 years ago in  0 Future consideration

extracting data using the API from Audit Cross Section

I tried to find the sets of command using the API to extract data from the Audit Cross section, I believe it would be very great if this feature is available in Ram Concept if not already.
Guest 9 months ago in  0 Future consideration

Tendons Shop drawing chairs

Adding tendons shop drawing chairs (each 1m or any distance specified by the user) will be very effective and useful for users and for bentley, all other softwares for PT design have now tendons shop drawing this will make a big disadvantage for r...
hytham ahmed over 3 years ago in  3 Planned

Incorporate RAM custom templates for RAM concept models embedded in RSS models

Please add feature to be able to have custom templates for ram concept models that are embedded in ram structural models.
Guest over 2 years ago in  1 Future consideration

Expose design strips through the RAM Concept API

The missing component in a largely automated workflow is the ability to draw design strips/span segments, specify settings and read results through the RAM API. It would be a massive help if this functionality was incorporated. We've seen other co...
Guest almost 2 years ago in  0 Future consideration

Shop Drawing for cables in Revit and AutoCAD with consider a duct height.

No description provided
Guest about 2 years ago in  0 Planned

Include plan generation when adding Load Combinations with the API

Being able to create custom load combos using the API would be extremely useful if there was an option to specify which plans to generate along with each combo (stress, force, deflection, reactions, soil bearing). Having to create the plans manual...
Guest about 1 year ago in  0 Future consideration

Format bar length as 8'-4" rather than 8.33'.

I'd like to specify the bar length format consistently as 8'-4" rather than a decimal value based on the current units (8.33 or 100).
Guest over 1 year ago in  0 Future consideration

Prestressed Flexural Member Shear Design

It looks like RAM Concept uses an approximate method per Table 22.5.8.2 for calculating Vc and does not use the alternative option Vc per 22.5.8.3. There are cases where the shear capacity per 22.5.8.3 is less than the approximate method Per Tabl...